Home    中文  
 
  • Search
  • lucene Search
  • Citation
  • Fig/Tab
  • Adv Search
Just Accepted  |  Current Issue  |  Archive  |  Featured Articles  |  Most Read  |  Most Download  |  Most Cited

Chinese Journal of Laparoscopic Surgery(Electronic Edition) ›› 2016, Vol. 09 ›› Issue (02): 93-95. doi: 10.3877/cma.j.issn.1674-6899.2016.02.011

Special Issue:

• Original Article • Previous Articles     Next Articles

Early experience of removal of thoracic tumor under single-hole thoracoscope by using single joint equipment

Tao Liu 1, Yingtong Huang 1, Xiaoying Yan 1, Jianji Guo 1, Huafu Zhou 1 , ( ), Yongyong Wang 1   

  1. 1. Department of Cardiothorac Surgery, the First Affiliated Hospital of Guangxi Medical University, Nanning 530007, China
  • Received:2016-01-09 Online:2016-04-30 Published:2016-04-30
  • Contact: Huafu Zhou
  • About author:
    Corresponding author: Zhou Huafu, Email:

Abstract:

Objective

Discuss the feasibility of removal of thoracic tumor under Single-hole thoracoscope by using Single joint equipment, and summary the operation method.

Methods

From Oct. to Dec. 2015, 7 cases with removal of thoracic tumor under Single-hole Thoracoscope by using Single joint equipment in cardiothoracic surgery department of west hospital ward, first affiliated hospital of Guangxi medical university (4 males, 3 female; 3 with pulmonary lobectomy and lymphadenectomy, 2 with removal of mediastinal tumor, 1 with wedge resection of bilateral lung), all surgicals were done with Single-hole thoracoscope by using Single joint equipment.

Results

Among 7 cases, none was turned to thoracic surgery and Porous thoracoscope surgery, having surgery related complications. Time of operation: pulmonary lobectomy and lymphadenectomy 98-142 min(126 min on average), mediastinal tumor removal 48-74 min(62 min on average), wedge resection of bilateral lung 42 min; amount of bleeding 30-350 ml(120 ml on average). Postoperative pathological: 3 lung adenocarcinoma, 1 squamous cell carcinomas, 1 mediastinal teratoma, 1 thymoma, 1 bilateral lung tuberculoma, 1 lung adenocarcinoma merging pulmonary chondroma and pulmonary hamartoma.

Conclusions

It’s safe and workable to carry out the removal of thoracic tumor under Single-hole thoracoscope by using Single joint equipment, especially fitting to the hospital lack of double-jointed thoracoscopic instrumentation bullae.

Key words: Single joint equipment, Single-hole thoracoscope, Thoracic tumor, Operation experience

京ICP 备07035254号-20
Copyright © Chinese Journal of Laparoscopic Surgery(Electronic Edition), All Rights Reserved.
Tel: 01066937562 E-mail: zhonghuaqiangjing@126.com
Powered by Beijing Magtech Co. Ltd