Home    中文  
 
  • Search
  • lucene Search
  • Citation
  • Fig/Tab
  • Adv Search
Just Accepted  |  Current Issue  |  Archive  |  Featured Articles  |  Most Read  |  Most Download  |  Most Cited

Chinese Journal of Laparoscopic Surgery(Electronic Edition) ›› 2023, Vol. 16 ›› Issue (03): 183-185. doi: 10.3877/cma.j.issn.1674-6899.2023.03.012

• Clinical Technology • Previous Articles    

Robotic colorectal resection with hand-sewn anastomosis of the digestive tract and nature orifice specimen extraction

Qicong Zhu1, Weiwei Jin1, Yiping Mou1,(), Yuanyu Wang1, Chao Lu1, Yucheng Zhou1, Tao Xia1   

  1. 1. Department of General Surgery, Division of Gastrointestinal and Pancreatic Surgery, Zhejiang Provincial People′s Hospital, Hangzhou 310014, China; Key Laboratory of Gastroenterology of Zhejiang Province, Hangzhou 310014, China
  • Received:2023-04-10 Online:2023-06-30 Published:2023-08-03
  • Contact: Yiping Mou

Abstract:

Objective

To investigate the feasibility and safety of robotic colorectal resection with hand-sewn anastomosis of the digestive tract and nature orifice specimen extraction.

Methods

The clinical date of 10 patients diagnosed with colorectal tumor who were treated with robotic colorectal resection with hand-sewn anastomosis of the digestive tract and nature orifice specimen extraction from May 2020 to July 2022 at the Division of Gastrointestinal and Pancreatic Surgery, Zhejiang Provincial People’s Hospital were retrospectively studied.

Results

There were 4 males and 6 females, with the age range from 33 to 82 years, received robotic colorectal resection with hand-sewn anastomosis of the digestive tract and nature orifice specimen extraction. The surgical specimen is removed through the rectum. The median operative time was 120(ranged 100 to 190)minutes. The intraoperative blood loss was 40(ranged 10 to 100)ml and there was no intraoperative blood transfusion. The median postoperative hospital stay was 10(ranged 8 to 18)days. There were no transit open surgery, re-operation and mortality. Perioperative complications (Clavien-Dindo grade): 1 case of grade Ⅲ, 2 cases of grade Ⅱ, 1 case of grade Ⅰ; 1 case developed anastomotic leakage, successful through conservative treatment.

Conclusion

Robotic colorectal resection with hand-sewn anastomosis of the digestive tract and nature orifice specimen extraction was effective and safe to treat colorectal tumor with the improvement of intra-abdominal anastomosis technology.

Key words: Robotic colorectal surgery, Colorectal tumor, Nature orifice specimen extraction, Hand-sewn anastomosis